Area: Reheating Furnace
Slab detection inside a reheating furnace
Detection form the above is difficult due to the presence of water and heavy steam formation. Spurious triggering was caused, which induced alignment errors. Infrared light at longer wavelength. High functional reserve : 1500meters. Easy alignment using 2 LED Home Case Studies Exit slab detection inside reheating furnace Exit slab detection inside reheating furnace Home …
Prevent slab pile up by view inside the RHF
Home Case Studies Prevent slab pile up by view inside the RHF Prevent slab pile up by view inside the RHF Operator to get inside view of the walking beam furnace. Prevent any slab pile-up leading to loss in production. Visual camera to operate in high ambient temperature to withstand upto 2200 °C. Rugged camera …
Walking Beam Position using Rope Length Transmitter
Heavy duty rope length transmitter was designed for these harsh environment conditions:- higher force rope and thicker rope of 2mm with PA coating instead of standard 0.8mm / 1.35mm. Rope can be easily changed by the customer themselves. Open designed with grooves allowed dust not getting collected inside the drum. Home Case Studies Walking Beam …
Walking Beam Position using Rope Length TransmitterRead More
Measuring temperature inside metal in Reheating Furnace
The short wavelength high performance pyrometer with wall mounting monitors temperature of metal inside the reheating furnace and ensures slabs are optimally heated. Direct temperature measurement of metal is made possible with option to have a video view of the inside of the furnace. Home Case Studies Measuring temperature inside metal in Reheating Furnace Measuring …
Measuring temperature inside metal in Reheating FurnaceRead More
Slab Centering at Charging side
Home Case Studies Slab Centering at Charging side High ambient temperature IR Light Barrier / Photocell) is used for the detection of thin slabs inside the tunnel reheating furnace. The system with fiber optic cables (290⁰C ambient) and separate electronics is installed 2m away from the heat zone. This allowed the photocell to operate in …