In a reheating furnace, the input materials from the continuous caster (slabs, blooms or billets) are first heated to a temperature above the recrystallization temperature. Reheating furnaces can be designed as awalking beam, pusher-type or rotary hearth furnaces. In the walking beam furnace presented here, a hydraulically operated walking beam system transports the billets through the furnace at a constant speed applying a lift and feed motion.
Flexible, Accurate, Fast
Especially suited for measurement of extremely high metal temperature
Largely resistant against dust, steam, and dirt observation windows….
Temperature Range: 250° C to 3000° C
CT Ratio 1M : 450°C to 3,000°C
CT Ratio 2M: 250°C to 3000°C
Superior optical resolution: 40:1
Smallest spot size: 7.7 mm
Fastest response time: 5 ms
Protection: IP 65 rating….